This guide explains all Electrolux Dryer error codes (CH series) with simple troubleshooting steps to help you identify and fix common issues safely before calling a technician.
E64
Heating Element Fault
- Check heating element continuity using a multimeter.
- Inspect wiring connections for burns or loose terminals.
- Ensure proper airflow through the dryer.
- Replace the heating element if defective.
E65
Thermistor Error
- Inspect thermistor wiring connections.
- Test resistance values at room temperature.
- Check for moisture or corrosion damage.
- Replace thermistor if readings are outside specifications.
E66
Overheating Detected
- Clean lint filter and exhaust vent system.
- Inspect airflow restrictions throughout ductwork.
- Allow dryer to cool before restarting.
- Check thermal fuse and high-limit thermostat.
E68
Control Board Failure
- Disconnect power for 5–10 minutes.
- Inspect control board for damaged components.
- Check wiring harness connections.
- Replace electronic control board if necessary.
E71
Motor Relay Fault
- Inspect motor relay on the control board.
- Check motor wiring connections.
- Test relay switching operation.
- Replace control board if relay is defective.
E72
Door Switch Issue
- Check door latch alignment.
- Inspect door switch wiring.
- Test switch continuity.
- Replace door switch if faulty.
E73
Temperature Sensor Fault
- Inspect temperature sensor connections.
- Check sensor resistance values.
- Verify wiring harness condition.
- Replace sensor if defective.
E74
Temperature Sensor Mismatch
- Verify all temperature sensors are connected correctly.
- Confirm correct sensor type is installed.
- Inspect harness wiring for damage.
- Replace sensor or control board if mismatch continues.
E82
User Interface Communication Error
- Reset dryer power supply.
- Inspect display panel wiring connections.
- Check communication cable between boards.
- Replace interface board if necessary.
E91
Main Board Communication Failure
- Check communication wiring harness.
- Inspect connectors for corrosion.
- Restart appliance and retest.
- Replace control board if fault remains.
E92
Configuration Error
- Verify appliance configuration settings.
- Check software programming data.
- Reset control board if available.
- Reprogram or replace board if required.
E93
EEPROM Memory Error
- Disconnect power and restart appliance.
- Check control board connections.
- Inspect PCB for damage.
- Replace control board if memory failure persists.
E5A
Motor Control Overheating
- Allow dryer to cool down completely.
- Check ventilation and airflow.
- Inspect motor control board.
- Replace motor control module if needed.
E5B
Supply Voltage Too Low
- Verify incoming voltage at outlet.
- Inspect power cord and connections.
- Avoid using extension cords.
- Contact an electrician if voltage remains unstable.
E5C
Supply Voltage Too High
- Measure supply voltage levels.
- Inspect electrical installation.
- Disconnect appliance until voltage normalizes.
- Contact a qualified electrician if necessary.
E41
Door Not Closed
- Close the dryer door securely.
- Inspect door latch mechanism.
- Check for clothing blocking closure.
- Replace latch assembly if damaged.
E51
Motor Triac Fault
- Inspect motor control circuitry.
- Check motor wiring connections.
- Test motor operation.
- Replace motor control board if required.
E52
No Motor Signal Detected
- Check motor tachometer connections.
- Inspect drive motor wiring.
- Test motor operation manually.
- Replace motor if signal remains absent.
E10
Water Supply / Sensor Issue
- Check inlet water system (if steam function is used).
- Inspect sensor connections for damage.
- Restart the dryer to reset system.
- Replace faulty sensor if error persists.
E20
Drain System Fault
- Check drain hose for blockage or kinks.
- Clean lint and water collection system.
- Inspect pump (condensing models).
- Reset unit after cleaning.
E30
Door Lock Error
- Ensure door is fully closed.
- Inspect door latch mechanism.
- Check door switch wiring.
- Replace latch if defective.
E40
Door Open / Safety Lock Active
- Close dryer door securely.
- Remove clothing blocking the seal.
- Inspect door sensor alignment.
- Reset dryer and retry cycle.
E50
Motor / Drum Rotation Failure
- Check drum for obstruction or overload.
- Inspect drive belt condition.
- Test motor operation.
- Replace motor if failure continues.
E60
Heating System Fault
- Check heating element continuity.
- Inspect thermal fuse and thermostat.
- Clean lint filter and airflow system.
- Replace heater if defective.
E61
Temperature Sensor Fault
- Inspect thermistor wiring connections.
- Test resistance readings.
- Check for moisture or corrosion.
- Replace sensor if readings are abnormal.
E70
Overheating Protection Activated
- Clean lint filter and exhaust vents.
- Ensure proper airflow around dryer.
- Allow unit to cool before restarting.
- Check thermal fuse condition.
E80
Control Board Communication Error
- Disconnect power for 5–10 minutes.
- Check wiring harness connections.
- Inspect control board for damage.
- Replace PCB if error persists.
E90
Configuration / EEPROM Error
- Restart the dryer system.
- Check control board settings.
- Inspect PCB memory module.
- Replace board if configuration fails.